DHW Tanks

  • Used for indirect domestic hot water heating with solar support in an upright version with one internal heat exchanger.
  • Made of steel S235JR+AR or stainless steel, designed according to DIN EN 12897 and the Pressure Equipment Directive 2014/68/EU.
  • Enameling for hygienic perfect drinking water is performed according to DIN 4835 T3.
  • DHW tank up to 500 litres insulated with non-removable highly efficient insulation system according to DIN 4102-1 material class B2;
    DHW tank > 500 to 1000 litre insulated with 100mm; DHW tank > 1000 litres with 120mm removable fleece insulation, according to DIN 4102-1 material class B2. Tanks up to 2000 litres are supplied ready-insulated. Tanks greater than 3000 litres are transported horizontally, without insulation. Insulation must be ordered separately.
  • Drinking water tank up to 500 litres available in energy efficiency classes A, B and C. DHW tank > 500 litres only available in energy efficiency class C.
  • Made and assembled in Germany.
  • Available with capacities 150-3000 litres.
Type AF 150/1M_B AF 200/1M_B AF 300/1M_B AF 400/1M_B AF 500/1M_B AF 750/1_C
Colour Silver or white Silver or white Silver or white Silver or white Silver or white Silver or white
Nominal capacity 156 l 197 l 303 l 384 l 476 l 750 l
Energy efficiency class B B B B B C
Max. perm. operating temperature 95 95 95 95 95 95
Perm. operating temperature heat exchanger 110 110 110 110 110 110
Max. perm. operating pressure 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar
Perm. operating pressure heat exchanger 16 bar 16 bar 16 bar 16 bar 16 bar 16 bar
Heat maintaining losses 56 W 52 W 70 W 68 W 78 W 123 W
Drinking water connection R 3/4" R 3/4" R 1" R 1" R 1" R 1 1/4"
Circulation connection R 3/4" R 3/4" R 3/4" R 3/4" R 3/4" R 3/4"
Connection cold/hot water R 3/4" R 3/4" R 1" R 1" R 1" R 1 1/4"
Connection flow/return R 1" R 1" R 1" R 1" R 1" R 1 1/4"
Heating surface bottom 0.75 m² 0.95 m² 1.40 m² 1.80 m² 1.90 m² 3.70 m²
Insulation type foil jacket foil jacket foil jacket foil jacket foil jacket foil jacket
Insulation thickness 75 mm 75 mm 51.5 mm 76.5 mm 76.5 mm 100 mm
Diameter 540 mm 600 mm 700 mm 750 mm 750 mm 950 mm
Height 1219 mm 1475 mm 1334 mm 1631 mm 1961 mm 2023 mm
Depth 540 mm 600 mm 700 mm 750 mm 750 mm 950 mm
Tilt dimension approx. 1270 mm 1525 mm 1441 mm 1719 mm 2029 mm 2104 mm
Weight 47.20 kg 79.00 kg 82.80 kg 137.00 kg 189.00 kg 229.50 kg

ــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ

  • Used for indirect domestic hot water heating with solar support in an upright version with two internal heat exchangers.
  • Made of steel S235JR+AR or stainless steel, designed according to DIN EN 12897 and the Pressure Equipment Directive 2014/68/EU.
  • Enameling for hygienic perfect drinking water is performed according to DIN 4835 T3.
  • DHW tank up to 500 litres insulated with non-removable highly efficient insulation system according to DIN 4102-1 material class B2;
    DHW tank > 500 to 1000 litre insulated with 100mm; DHW tank > 1000 litres with 120mm removable fleece insulation, according to DIN 4102-1 material class B2. Tanks up to 2000 litres are supplied ready-insulated. Tanks greater than 3000 litres are transported horizontally, without insulation. Insulation must be ordered separately.
  • Drinking water tank up to 500 litres available in energy efficiency classes A, B and C. DHW tank > 500 litres only available in energy efficiency class C.
  • Made and assembled in Germany.
  • Available with capacities 150-3000 litres.
Type AF 200/2_B AF 300/2_B AF 400/2_B AF 500/2_B AF 750/2_B
Colour Silver or white Silver or white Silver or white Silver or white Silver or white
Nominal capacity 196 l 303 l 382 l 482 l 751 l
Energy efficiency class B B B B C
Max. perm. operating temperature 95 95 95 95 95
Perm. operating temperature heat exchanger 110 110 110 110 110
Max. perm. operating pressure 10 bar 10 bar 10 bar 10 bar 10 bar
Perm. operating pressure heat exchanger 16 bar 16 bar 16 bar 16 bar 16 bar
Heat maintaining losses 52 W 70 W 68 W 78 W 129 W
Drinking water connection R 3/4" R 1" R 1" R 1/4" R 1 1/4"
Circulation connection R 3/4" R 3/4" R 3/4" R 3/4" R 3/4"
Connection cold/hot water R 3/4" R 1" R 1" R 1" R 1 1/4"
Connection flow/return R 1" R 1" R 1" R 1" R 1"
Heating surface top 0.75 m² 0.85 m² 1.05 m² 1.30 m² 1.17 m²
Heating surface bottom 0.95 m² 1.45 m² 1.80 m² 1.90 m² 1.93 m²
Insulation type foil jacket foil jacket foil jacket foil jacket foil jacket
Insulation thickness 75 mm 51.5 mm 76.5 mm 76.5 mm 100 mm
Diameter 600 mm 700 mm 750 mm 750 mm 950 mm
Height 1475 mm 1294 mm 1657 mm 1961 mm 2035 mm
Depth 600 mm 700 mm 750 mm 750 mm 950 mm
Tilt dimension approx. 1524 mm 1438 mm 1721 mm 2029 mm 2104 mm
Weight 84.00 kg 84.00 kg 149.00 kg 179.00 kg 215.70 kg